Showing results: 661 - 675 of 2628 items found.
-
Technology Products
Primary current injection kits are used to test and commission Circuit Breakers, Bus Bars, CTs, Relays, MCCs, PCCs etc. These are also used for high current injection and simultaneously measuring voltage drops and hot spots in bus-bar joints, Circuit Breaker Contacts etc.
-
WT4000 -
Lisun Electronics Inc.
• Measure parameter: 1) Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic. 2) Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis. • Startup: Startup lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time; • Simultaneously display on 8 windows for input and output parameters, convenient for comparison and analysis; • Test preheat energy, filament preheat time. And the parameters changes from 0 to 5s of filament voltage, filament current and filament power; • Up to 1MHz lrms test content to every EB; • Analysis symmetry of high Frequency curve of lout; • 12-bit high-speed A/D, sampling rate up to 10MHz, can easily analyse signal curve of output; • Finish an input and output testing at the same time within 1 minute; • Portable, can test, display, print without computer. Test report include data and curve, comply with international standard; • Communication port for PC, run under Windows98 or Windows2000, English Version available.
-
SA 30i -
Scope T&M Pvt, Ltd.
SA 30i, the Leakage Current Analyser from SCOPE is a State of the Art, On-line test system for Residual Life Assessment of Metal Oxide Surge Arresters. The instrument measures and directly displays the values of Total Leakage Current and Third Harmonic Resistive Leakage Current. It provides system harmonic compensation as per IEC 60099-5-B2. It provides Corrected Resistive Leakage Current after applying correction factors for change in system voltage & temperature.
-
72-7730A -
Tenma
Digital multimeter is a 20,000 counts and 4-1/2 digits with steady operation. The meter can measure AC voltage and current, DC voltage and current, resistance, capacitance, temperature frequency, diodes, continuity, 4 to 20mA loop, Max/Min, relative mode but also has data store, data recall, AC true RMS, AC+DC, low battery display, double display backlight, automatic power off and full overload protection.
-
EL-R Series -
Aim-TTi
Single outputs, 30V/1A, 18V/3.3A, 56V/1.1A, 15V/5A, 30V/3ASingle, dual or triple outputs, 30V/2AIndependent digital voltage and current meters for each output with 4 digit resolutionSwitchable local or remote sensingConstant voltage or constant current operationVariable 1.5 - 5.0V auxiliary output at 2A (EL302RT)Compact design uses less bench spaceSilent fan-free coolingDC output switches, automatic mode indicationRS232 or USB controlled models available (30V/2A single)
-
SFJ018 -
Shanghai Launch Electric Co., Ltd.
SFJ018 relay protection test cabinet uses double carbon brushes regulator, big buttons for regulating AC/DC voltage, current under large loading, small buttons for regulating AC/DC voltage, current under small loading,. The two output channels could work simultaneously. It also take use of digital meters of Grade 0.5, sensor of high accuracy, six digital display stop watch, satisfying requirements for time measurement.
-
E-Max Instruments
The Analog Optical Isolator module is a single isolated current in / current out or voltage in / voltage out channel of physical separation and electrical isolation for establishing and maintaining the independence of Class 1E equipment from non -Class 1E instrumentation circuits. Input-to-Output isolation has a steady-state isolation capability of 2500 volts AC rms. This isolation will be maintained between:a) input to output signalsb) input to output powerc) output signal to input power
-
YAV90075 -
6TL Engineering
This module is ideal to cover power supply needs in fixture proyects. For voltages up to 20V, through two regulable channels. With an minimum input level of 2.7V and a maximum of 20V, has only 340mV of drop voltage. The maximum current supplied for each channel is 1.5A.
-
Shanghai MCP Corp
Taut-Band movement.26 measuring range with Min. 1mV and 100uA(MS506-A) both in AC and DC.Zero at midpoint function (voltage meter,current meter and galvanometer 3 in 1).Overload warning LED indicator.Input impedance:100kΩ at all voltage ranges.Battery test function
-
Fluke T6-600 -
Iconic Engineering Limited
Fluke T6-600 Electrical Tester field sense technology for ac voltage, current, and frequency measurement without making electrical contact to live voltage. The most important things about the Fluke T6-600 electrical tester that always provide an accurate measurement in any environment.
-
HSL-DI32-DB-N -
ADLINK Technology Inc.
*Slave ID consumption: 2 - N: for 32-CH NPN sinking type sensor inputs or dry contact*Photo couple isolation voltage: 2500Vrms*Input impedance: 4.7KΩ*Input current: ??10mA (Max), ??12.5mA (Peak)*Input voltage: ??40V (Max)
-
cPCI-6208/6216 Series -
ADLINK Technology Inc.
- PICMG 2.0 Rev 2.1- 16-bit D/A resolution- 16-CH voltage on 6216V- 8-CH voltage outputs on 6208A and 6208V- 8-CH current outputs on 6208A- Bipolar analog output range- 4-CH TTL DI and 4-CH TTL DO- Rear I/O available
-
BT2152B -
Keysight Technologies
The Self-Discharge Analyzer accurately measures cell self-discharge current and cell voltage. Depending on the characteristics of the cells, measurements are directly made in minutes or hours instead of taking days or weeks using open-circuit cell voltage measurements to indicate which cells are good vs. bad.
-
ST1000 -
Shenzhen Star Instrument Co., Ltd.
The ST1000 three-phase reference meter incorporates high-precision A/D converter, DSP, wide-range measuring and embedding industrial PC technologies. It has a high accuracy of class 0.01. The voltage measuring range (phase voltage): 1V~480V, current measuring range: 1mA~120A.
-
PTE-100-C -
EUROSMC, S.A.
The PTE-100-C is a portable Universal test equipment for testing electromechanical, electronic, and digital relays. The equipment can output a variable current up to 250A, a variable AC Voltage up to 250V, a variable DC Voltage up to 350V. Also the unit incorporates a variable stabilized auxiliary DC Voltage supply up to 250V and a fixed AC Voltage output up to 110V, which can be variable with the PTE-FCF option.